galvanometer-driven optical scanner Search Results


90
MicroMax Inc cambridge 6220 xy scanner
Cambridge 6220 Xy Scanner, supplied by MicroMax Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/galvanometer-driven+optical+scanner/cambridge+6220+xy+scanner/us10539772-789-15-22
Average 90 stars, based on 1 article reviews
cambridge 6220 xy scanner - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Lumonics Inc galvanometer optical scanner model 000-g112
Galvanometer Optical Scanner Model 000 G112, supplied by Lumonics Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/galvanometer-driven+optical+scanner/optical+scanner+000+g112/pmc02840658-73-11-13
Average 90 stars, based on 1 article reviews
galvanometer optical scanner model 000-g112 - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

86
Thorlabs galvanometer scanner
Galvanometer Scanner, supplied by Thorlabs, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/galvanometer-driven+optical+scanner/galvanometer/10__1364_slash_oe__27__001425-28-23-26
Average 86 stars, based on 1 article reviews
galvanometer scanner - by Bioz Stars, 2026-09
86/100 stars
  Buy from Supplier

90
Dalsa corp drive electronics of the galvanometer scanners
Drive Electronics Of The Galvanometer Scanners, supplied by Dalsa corp, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/galvanometer-driven+optical+scanner/drive+electronics+of+the+galvanometer+scanners/10__1117_slash_1__jbo__23__7__071207-52-18-28
Average 90 stars, based on 1 article reviews
drive electronics of the galvanometer scanners - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Raylase GmbH raylase scanner
Raylase Scanner, supplied by Raylase GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/galvanometer-driven+optical+scanner/scanning+head+raylase+ss+iie+10/10__1016_slash_j__matdes__2020__109411-87-17-17
Average 90 stars, based on 1 article reviews
raylase scanner - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

86
Thorlabs fiber collimator
Fiber Collimator, supplied by Thorlabs, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/galvanometer-driven+optical+scanner/collimator+fiber/10__1364_slash_oe__27__001425-28-12-15
Average 86 stars, based on 1 article reviews
fiber collimator - by Bioz Stars, 2026-09
86/100 stars
  Buy from Supplier

90
Dalsa corp line scan detector dalsa il c6
Line Scan Detector Dalsa Il C6, supplied by Dalsa corp, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/galvanometer-driven+optical+scanner/line+scan+detector+dalsa+il+c6/10__1117_slash_1__jbo__23__7__071207-52-25-28
Average 90 stars, based on 1 article reviews
line scan detector dalsa il c6 - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
MicroMax Inc galvanometer scanner 8320k
Schematics of LAORS system with Zemax ray tracing Input beam: optical pulses from a pulsed laser source; resonant mirror: CRS 4 kHz (Cambridge Technology, USA); <t>galvanometer</t> mirror: <t>8320K</t> (Cambridge Technology, USA); scan lens: LSM05-BB, effective focal length (EFL) of 110 mm (Thorlabs, USA); custom tube lens: a combination of 3 plano-convex lenses (Edmund Optics: 86-925, EFL of 500 mm), combined EFL of 166.7 mm; objective lens: Olympus XLUMPlanFl, 20×/0.95W. Note that multiple colors are utilized to better distinguish the rays under different scanning angles by the resonant and galvanometer scanning mirrors (see <xref ref-type=Figure 2 for more information on optical performance at different scanning angles). " width="250" height="auto" />
Galvanometer Scanner 8320k, supplied by MicroMax Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/galvanometer-driven+optical+scanner/galvanometer+scanner+8320k/pmc09048148-122-50-54
Average 90 stars, based on 1 article reviews
galvanometer scanner 8320k - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Hamamatsu c6438-01
Schematics of LAORS system with Zemax ray tracing Input beam: optical pulses from a pulsed laser source; resonant mirror: CRS 4 kHz (Cambridge Technology, USA); <t>galvanometer</t> mirror: <t>8320K</t> (Cambridge Technology, USA); scan lens: LSM05-BB, effective focal length (EFL) of 110 mm (Thorlabs, USA); custom tube lens: a combination of 3 plano-convex lenses (Edmund Optics: 86-925, EFL of 500 mm), combined EFL of 166.7 mm; objective lens: Olympus XLUMPlanFl, 20×/0.95W. Note that multiple colors are utilized to better distinguish the rays under different scanning angles by the resonant and galvanometer scanning mirrors (see <xref ref-type=Figure 2 for more information on optical performance at different scanning angles). " width="250" height="auto" />
C6438 01, supplied by Hamamatsu, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/galvanometer-driven+optical+scanner/transimpedance+amplifier+c6438+01/pmc08450254__mmc1-14-40-41
Average 90 stars, based on 1 article reviews
c6438-01 - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

86
Edmund Optics plano convex lenses
Schematics of LAORS system with Zemax ray tracing Input beam: optical pulses from a pulsed laser source; resonant mirror: CRS 4 kHz (Cambridge Technology, USA); <t>galvanometer</t> mirror: <t>8320K</t> (Cambridge Technology, USA); scan lens: LSM05-BB, effective focal length (EFL) of 110 mm (Thorlabs, USA); custom tube lens: a combination of 3 plano-convex lenses (Edmund Optics: 86-925, EFL of 500 mm), combined EFL of 166.7 mm; objective lens: Olympus XLUMPlanFl, 20×/0.95W. Note that multiple colors are utilized to better distinguish the rays under different scanning angles by the resonant and galvanometer scanning mirrors (see <xref ref-type=Figure 2 for more information on optical performance at different scanning angles). " width="250" height="auto" />
Plano Convex Lenses, supplied by Edmund Optics, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/galvanometer-driven+optical+scanner/convex+lens/pmc09048148-122-91-93
Average 86 stars, based on 1 article reviews
plano convex lenses - by Bioz Stars, 2026-09
86/100 stars
  Buy from Supplier

86
Thorlabs general scan lens
Schematics of LAORS system with Zemax ray tracing Input beam: optical pulses from a pulsed laser source; resonant mirror: CRS 4 kHz (Cambridge Technology, USA); <t>galvanometer</t> mirror: <t>8320K</t> (Cambridge Technology, USA); scan lens: LSM05-BB, effective focal length (EFL) of 110 mm (Thorlabs, USA); custom tube lens: a combination of 3 plano-convex lenses (Edmund Optics: 86-925, EFL of 500 mm), combined EFL of 166.7 mm; objective lens: Olympus XLUMPlanFl, 20×/0.95W. Note that multiple colors are utilized to better distinguish the rays under different scanning angles by the resonant and galvanometer scanning mirrors (see <xref ref-type=Figure 2 for more information on optical performance at different scanning angles). " width="250" height="auto" />
General Scan Lens, supplied by Thorlabs, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/galvanometer-driven+optical+scanner/lens+scanning/pmc09048148-122-66-70
Average 86 stars, based on 1 article reviews
general scan lens - by Bioz Stars, 2026-09
86/100 stars
  Buy from Supplier

90
Vincent Associates shutter drive unit vcm-di
Schematics of LAORS system with Zemax ray tracing Input beam: optical pulses from a pulsed laser source; resonant mirror: CRS 4 kHz (Cambridge Technology, USA); <t>galvanometer</t> mirror: <t>8320K</t> (Cambridge Technology, USA); scan lens: LSM05-BB, effective focal length (EFL) of 110 mm (Thorlabs, USA); custom tube lens: a combination of 3 plano-convex lenses (Edmund Optics: 86-925, EFL of 500 mm), combined EFL of 166.7 mm; objective lens: Olympus XLUMPlanFl, 20×/0.95W. Note that multiple colors are utilized to better distinguish the rays under different scanning angles by the resonant and galvanometer scanning mirrors (see <xref ref-type=Figure 2 for more information on optical performance at different scanning angles). " width="250" height="auto" />
Shutter Drive Unit Vcm Di, supplied by Vincent Associates, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/galvanometer-driven+optical+scanner/shutter+drive+unit+vcm+di/us10794802-1396-88-84
Average 90 stars, based on 1 article reviews
shutter drive unit vcm-di - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

Image Search Results


Schematics of LAORS system with Zemax ray tracing Input beam: optical pulses from a pulsed laser source; resonant mirror: CRS 4 kHz (Cambridge Technology, USA); galvanometer mirror: 8320K (Cambridge Technology, USA); scan lens: LSM05-BB, effective focal length (EFL) of 110 mm (Thorlabs, USA); custom tube lens: a combination of 3 plano-convex lenses (Edmund Optics: 86-925, EFL of 500 mm), combined EFL of 166.7 mm; objective lens: Olympus XLUMPlanFl, 20×/0.95W. Note that multiple colors are utilized to better distinguish the rays under different scanning angles by the resonant and galvanometer scanning mirrors (see <xref ref-type=Figure 2 for more information on optical performance at different scanning angles). " width="100%" height="100%">

Journal: STAR Protocols

Article Title: Construction of a high-NFOM multiphoton microscope with large-angle resonant raster scanning

doi: 10.1016/j.xpro.2022.101330

Figure Lengend Snippet: Schematics of LAORS system with Zemax ray tracing Input beam: optical pulses from a pulsed laser source; resonant mirror: CRS 4 kHz (Cambridge Technology, USA); galvanometer mirror: 8320K (Cambridge Technology, USA); scan lens: LSM05-BB, effective focal length (EFL) of 110 mm (Thorlabs, USA); custom tube lens: a combination of 3 plano-convex lenses (Edmund Optics: 86-925, EFL of 500 mm), combined EFL of 166.7 mm; objective lens: Olympus XLUMPlanFl, 20×/0.95W. Note that multiple colors are utilized to better distinguish the rays under different scanning angles by the resonant and galvanometer scanning mirrors (see Figure 2 for more information on optical performance at different scanning angles).

Article Snippet: Refer to depicting the essential elements of a large-angle optical raster scanning (LAORS) system, primarily comprising: a. a typical pulsed laser source with an adequate repetition rate (Fidelity 2, Coherent, USA), b. a raster scanning unit with a resonant scanner (CRS 4 kHz, driver: 311-149887) for fast X-axis and a galvanometer scanner (8320K, driver: MicroMax 671) for slow Y-axis (both from Cambridge Technology, USA), c. a general scan lens (LSM05-BB, Thorlabs, USA) with an effective focal length (EFL) of 110 mm, d. a dedicated tube lens was custom designed combining three plano-convex lenses (Edmund Optics: 86-925), each with clear aperture and EFL of 73.5 mm and 500 mm, respectively, resulting in a combined EFL of 166.7 mm, e. a high-NA and low magnification objective lens (Olympus XLUMPlanFl, 20×/0.95W) with an EFL of 9 mm.

Techniques:

Block diagram of the proposed control and data acquisition system The system comprises of- a computer: with i7-9800X 8-core processor and Nvidia Quadro RTX 8000 for CUDA-acceleration; a multifunction I/O card: PCIe-6341 (National Instruments Corporation, USA); a digitizer: ATS9440 (Alazar Technologies Inc., Canada); a 70 MHz pulsed laser source: Fidelity 2 Yb-Fiber Laser (Coherent Inc., USA); a resonant scanning system: CRS 4 kHz (driver: 311-149887), a galvanometer scanning system: 8320K (driver: MicroMax 671), Cambridge Technology, USA; a 16-bit digital to analog converter (DAC): 6757 (Cambridge Technology, USA); a voltage buffer: 50LD (Thorlabs, USA); a power splitter: ZFRSC-42-S+ (Mini-Circuits, USA); a high voltage power supply: C9525 (Hamamatsu Photonics, Japan); a transimpedance amplifier: C6438-01 (Hamamatsu Photonics, Japan); a multi-axis stage controller: SHOT-304GS, and three linear stages: 2 × TSDM40-15X and 1 × SGSP80-20ZF (Sigma Koki, Japan); a software: C++ written custom application.

Journal: STAR Protocols

Article Title: Construction of a high-NFOM multiphoton microscope with large-angle resonant raster scanning

doi: 10.1016/j.xpro.2022.101330

Figure Lengend Snippet: Block diagram of the proposed control and data acquisition system The system comprises of- a computer: with i7-9800X 8-core processor and Nvidia Quadro RTX 8000 for CUDA-acceleration; a multifunction I/O card: PCIe-6341 (National Instruments Corporation, USA); a digitizer: ATS9440 (Alazar Technologies Inc., Canada); a 70 MHz pulsed laser source: Fidelity 2 Yb-Fiber Laser (Coherent Inc., USA); a resonant scanning system: CRS 4 kHz (driver: 311-149887), a galvanometer scanning system: 8320K (driver: MicroMax 671), Cambridge Technology, USA; a 16-bit digital to analog converter (DAC): 6757 (Cambridge Technology, USA); a voltage buffer: 50LD (Thorlabs, USA); a power splitter: ZFRSC-42-S+ (Mini-Circuits, USA); a high voltage power supply: C9525 (Hamamatsu Photonics, Japan); a transimpedance amplifier: C6438-01 (Hamamatsu Photonics, Japan); a multi-axis stage controller: SHOT-304GS, and three linear stages: 2 × TSDM40-15X and 1 × SGSP80-20ZF (Sigma Koki, Japan); a software: C++ written custom application.

Article Snippet: Refer to depicting the essential elements of a large-angle optical raster scanning (LAORS) system, primarily comprising: a. a typical pulsed laser source with an adequate repetition rate (Fidelity 2, Coherent, USA), b. a raster scanning unit with a resonant scanner (CRS 4 kHz, driver: 311-149887) for fast X-axis and a galvanometer scanner (8320K, driver: MicroMax 671) for slow Y-axis (both from Cambridge Technology, USA), c. a general scan lens (LSM05-BB, Thorlabs, USA) with an effective focal length (EFL) of 110 mm, d. a dedicated tube lens was custom designed combining three plano-convex lenses (Edmund Optics: 86-925), each with clear aperture and EFL of 73.5 mm and 500 mm, respectively, resulting in a combined EFL of 166.7 mm, e. a high-NA and low magnification objective lens (Olympus XLUMPlanFl, 20×/0.95W) with an EFL of 9 mm.

Techniques: Blocking Assay, Control, Software

Entering a few important settings prior to imaging (A) The Settings GUI with multiple panels for resonant & galvanometer scanners, 3D stage, PMT high voltage (HV) supply, and additional parameters. (B and C) Calibration of resonant scanning angle, where B shows a simple method to estimate a scanning angle (optical) and C depicts a linear fitted plot for voltage vs optical scanning angle.

Journal: STAR Protocols

Article Title: Construction of a high-NFOM multiphoton microscope with large-angle resonant raster scanning

doi: 10.1016/j.xpro.2022.101330

Figure Lengend Snippet: Entering a few important settings prior to imaging (A) The Settings GUI with multiple panels for resonant & galvanometer scanners, 3D stage, PMT high voltage (HV) supply, and additional parameters. (B and C) Calibration of resonant scanning angle, where B shows a simple method to estimate a scanning angle (optical) and C depicts a linear fitted plot for voltage vs optical scanning angle.

Article Snippet: Refer to depicting the essential elements of a large-angle optical raster scanning (LAORS) system, primarily comprising: a. a typical pulsed laser source with an adequate repetition rate (Fidelity 2, Coherent, USA), b. a raster scanning unit with a resonant scanner (CRS 4 kHz, driver: 311-149887) for fast X-axis and a galvanometer scanner (8320K, driver: MicroMax 671) for slow Y-axis (both from Cambridge Technology, USA), c. a general scan lens (LSM05-BB, Thorlabs, USA) with an effective focal length (EFL) of 110 mm, d. a dedicated tube lens was custom designed combining three plano-convex lenses (Edmund Optics: 86-925), each with clear aperture and EFL of 73.5 mm and 500 mm, respectively, resulting in a combined EFL of 166.7 mm, e. a high-NA and low magnification objective lens (Olympus XLUMPlanFl, 20×/0.95W) with an EFL of 9 mm.

Techniques: Imaging

Journal: STAR Protocols

Article Title: Construction of a high-NFOM multiphoton microscope with large-angle resonant raster scanning

doi: 10.1016/j.xpro.2022.101330

Figure Lengend Snippet:

Article Snippet: Refer to depicting the essential elements of a large-angle optical raster scanning (LAORS) system, primarily comprising: a. a typical pulsed laser source with an adequate repetition rate (Fidelity 2, Coherent, USA), b. a raster scanning unit with a resonant scanner (CRS 4 kHz, driver: 311-149887) for fast X-axis and a galvanometer scanner (8320K, driver: MicroMax 671) for slow Y-axis (both from Cambridge Technology, USA), c. a general scan lens (LSM05-BB, Thorlabs, USA) with an effective focal length (EFL) of 110 mm, d. a dedicated tube lens was custom designed combining three plano-convex lenses (Edmund Optics: 86-925), each with clear aperture and EFL of 73.5 mm and 500 mm, respectively, resulting in a combined EFL of 166.7 mm, e. a high-NA and low magnification objective lens (Olympus XLUMPlanFl, 20×/0.95W) with an EFL of 9 mm.

Techniques: Software